Service Parts Disassembly
Phaser 3330 and WorkCentre 3335/3345 Xerox Internal Use Only
Service Manual
4-72
Note: When installing the LCD, there is a copper colored Ribbon Cable that connects the PBA SUB
to the OPE Joint. Be sure that this cable is fully installed. A small pair of needle nose pliers may be
needed. No information will be displayed on the LCD is this cable is not completely seated. See
following picture.