3.2 Operating Procedures for Utility Functions
3.2.6 Clear Alarm History (Fn006)
3-20
3.2.6
Clear Alarm History (Fn006)
You can use this utility function to clear the alarm history.
This utility function is the only way to clear the alarm history. The alarm
history is not cleared when you reset alarms or turn OFF the power sup-
ply to the SERVOPACK.
Preparations
Always check the following before you clear the alarm history.
• The parameters must not be write-prohibited (Fn010 must be set to
0000).
Operating Procedure
Step Operation Result
1
Press the Key to display the
Utility Mode Main Menu, and then
use the Key or Key to
select Fn006.
2
Press the Key.
The Fn006 (Clear Alarm History)
execution display will appear.
3
Press the Key.
Note: Press the Key to cancel
clearing the alarm history. The dis-
play will return to the Utility Mode
Main Menu.
The alarm history will be cleared.
When processing has been com-
pleted, the status display will flash
DONE for approximately one sec-
ond and then return to 1:BB.
1:BB
FUNCTION
Fn005:Prm Init
Fn006:AlmHis t Clr
Fn008:Mturn Clr
Fn009:Ref Adj
1:BB
Alarm His tory
S tart : [DATA]
Return: [S ET]
Data Clear
1:BB
Alarm His tory
S tart : [DATA]
Return: [S ET]
Data Clear