| Configuring Camera Settings | 193
Parameter Description Configuration
Method
Photometry
Configure the value of metering.
• Average
• Central
• Bottom
• Top
Default: Average.
Web user interface
Endpoint
CTP20/CTP18
Configuring the Mode of Brightness Priority
Procedure
1. Do one of the following:
• On your web user interface, go to Setting > Camera > Exposure.
• On your VCS: go to More > Settings > Basic > Camera > Exposure.
•
On your CTP20/CTP18, tap > Settings > Basic > Camera > Exposure.
2. Select Brightness Priority from the Exposure drop-down menu.
3. Configure and save the following settings:
Parameter Description Configuration Method
Brightness
Configure the value of brightness.
Note: the value is from 0 to 14. For
MeetingEye 400/PVT940/VC880/VC800/
VC500/VC200/VC200-E/PVT980/PVT950,
the default value is 6; for MeetingEye 600/
PVT960, the default value is 9.
Web user interface
Endpoint
CTP20/CTP18
Flicker
Configure the value of camera flicker
frequency.
The supported types are as follows:
• 50 Hz
• 60 Hz
The indoor lights powered by a 50Hz or 60Hz
power source may produce a flicker. You can
adjust the camera flicker frequency according
to the power source that the light is powered
by.
Default: 50 Hz.
Web user interface
Endpoint
CTP20/CTP18

Table of Contents

Other manuals for Yealink MeetingEye 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink MeetingEye 400 and is the answer not in the manual?

Yealink MeetingEye 400 Specifications

General IconGeneral
BrandYealink
ModelMeetingEye 400
CategoryConference System
LanguageEnglish

Related product manuals