Actual signals and parameters 219
3104 AR
OVERCURRE
NT
Activates/deactivates the automatic reset for the
overcurrent fault. Automatically resets the fault
(OVERCURRENT) after the delay set by parameter 3103
DELAY TIME.
DISABLE
DISABLE Inactive 0
ENABLE Active 1
3105 AR
OVERVOLTAG
E
Activates/deactivates the automatic reset for the
intermediate link overvoltage fault. Automatically resets the
fault (DC OVERVOLT) after the delay set by parameter
3103 DELAY TIME.
DISABLE
DISABLE Inactive 0
ENABLE Active 1
3106 AR
UNDERVOLTA
GE
Activates/deactivates the automatic reset for the
intermediate link undervoltage fault. Automatically resets
the fault (DC UNDERVOLT) after the delay set by parameter
3103 DELAY TIME.
DISABLE
DISABLE Inactive 0
ENABLE Active 1
3107 AR AI<MIN Activates/deactivates the automatic reset for fault AI<MIN
(analog input signal under the allowed minimum level) faults
AI1 LOSS (0007) and AI2 LOSS (0008). Automatically
resets the fault after the delay set by parameter 3103
DELAY TIME.
DISABLE
DISABLE Inactive 0
ENABLE Active
WARNING! The drive may restart even after a long
stop if the analog input signal is restored. Ensure that
the use of this feature does not cause danger.
1
3108 AR EXTERNAL
FLT
Activates/deactivates the automatic reset for faults EXT
FAULT 1 (0014) and EXT FAULT 2 (0015). Automatically
resets the fault after the delay set by parameter 3103
DELAY TIME.
DISABLE
DISABLE Inactive 0
ENABLE Active 1
All parameters
No. Name/Value Description Def/FbEq
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
sales@aotewell.com
+86-755-8660-6182

Table of Contents

Other manuals for ABB ACS310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS310 and is the answer not in the manual?

ABB ACS310 Specifications

General IconGeneral
Frequency50/60 Hz
IP RatingIP20
Control MethodScalar control
EMC FilterBuilt-in
Supply Voltage200 to 240 V, 380 to 480 V

Related product manuals