1SDH002031A1002 ECN000092998 Rev. B SACE Tmax XT2 – XT4 | 27
Advanced Menu
In the Advanced menu it is possible to configure the following protections:
Name
Parameters
SW package
Page
MCR
List in the dedicated chapter
Standard Protections
41
2I
List in the dedicated chapter
42
IU
List in the dedicated chapter
43
UV
(2)
List in the dedicated chapter
Voltage Protections
46
OV
(2)
List in the dedicated chapter
47
UV2
(2)
List in the dedicated chapter
47
OV2
(2)
List in the dedicated chapter
47
VU
(2)
List in the dedicated chapter
49
S(V)
(2)
List in the dedicated chapter
Advanced Voltage
Protections
50
S2(V)
(2)
List in the dedicated chapter
52
RV
(2)
List in the dedicated chapter
53
UF
(2)
List in the dedicated chapter
Frequency
Protections
54
OF
(2)
List in the dedicated chapter
55
UF2
(2)
List in the dedicated chapter
55
OF2
(2)
List in the dedicated chapter
56
RP
(2)
List in the dedicated chapter
Power Protections
58
D
(2)
List in the dedicated chapter
57
RQ
(2)
List in the dedicated chapter
62
OQ
(2)
List in the dedicated chapter
60
UP
(2)
List in the dedicated chapter
60
OP
(2)
List in the dedicated chapter
61
ROCOF
(2)
List in the dedicated chapter
ROCOF Protections
64
R STALL
(2)
List in the dedicated chapter
Motor Protections
67
R JAM
(2)
List in the dedicated chapter
67
UC
(2)
List in the dedicated chapter
68
U
(2)
List in the dedicated chapter
68
PTC
(2)
List in the dedicated chapter
69
V DIR, VINV
(2)
List in the dedicated chapter
Interface Protections
(IPS)
124
59 S1
(2)
List in the dedicated chapter
124
Synchrocheck
List in the dedicated chapter
NOTE 3
74
Alerts
Threshold 1 I1, Threshold 2 I1, Threshold
Iw1, Threshold Iw2, Phase Sequence
(2)
,
CosØ
(4)
Standard Protections
63
Warnings
VS Warning, FS Warning, FW1 Warning
Interface Protections
(IPS)
125, 126
Functions
External Trip, Trip Reset, Enable SETTING
B
(5)
Standard Protections
75
NOTES:
(1) if the Adaptive Protections package is available (page 65) and Dual Setting has
been enabled, an intermediate menu is made available before the list of
protections for the selection of the setting (Setting A / Setting B), the only menu
that is always present from Advanced is Functions
(2) available if required by the Trip unit model or if the relative additional SW package
has been enabled, where possible (see page 7 for the overview)
(3) available in the presence of the Ekip Synchrocheck module
(4) CosØ available if required by the Trip unit model or if the Power Protections
package has been enabled
(5) SETTING B available with the Adaptive Protection package

Table of Contents

Other manuals for ABB SACE Tmax XT2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB SACE Tmax XT2 and is the answer not in the manual?

ABB SACE Tmax XT2 Specifications

General IconGeneral
BrandABB
ModelSACE Tmax XT2
CategoryCircuit breakers
LanguageEnglish

Related product manuals