EasyManuals Logo
Home>Agilent Technologies>Inverter>33250A

Agilent Technologies 33250A User Manual

Agilent Technologies 33250A
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
163
Chapter 4 Remote Interface Reference
Output Configuration Commands
4
OUTPut:LOAD {<ohms>|INFinity|MINimum|MAXimum}
OUTPut:LOAD? [MINimum|MAXimum]
Select the desired output termination (i.e., the impedance of the load
attached to the output of the Agilent 33250A). The specified value is used
for amplitude, offset, and high/low level settings.
You can set the load to
any value from 1
to 10 k
.
MIN
selects 1
. MAX selects 10 k
.
INF sets
the output termination to “high impedance” (>10 k
Ω)
.
The default is 50
.
The :LOAD? query returns the current load setting in ohms or “9.9E+37”
(for “high impedance”).
The Agilent 33250A has a fixed series output impedance of 50 ohms
to the front-panel Output connector. If the actual load impedance is
different than the value specified, the displayed amplitude, offset,
and high/low levels will be incorrect.
If you change the output termination setting, the displayed output
amplitude, offset, and high/low levels are automatically adjusted
(and no error will be generated). For example, if you set the amplitude
to 10 Vpp and then change the output termination from 50 ohms to
“high impedance”, the amplitude displayed on the function generator’s
front-panel will
double
to 20 Vpp. If you change from “high impedance
to 50 ohms, the displayed amplitude will drop in half.
You cannot specify the output amplitude in dBm if the output
termination is currently set to “high impedance”. The units are
automatically converted to Vpp. See the VOLT:UNIT command on
page 165 for more information.

Table of Contents

Other manuals for Agilent Technologies 33250A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33250A and is the answer not in the manual?

Agilent Technologies 33250A Specifications

General IconGeneral
BrandAgilent Technologies
Model33250A
CategoryInverter
LanguageEnglish

Related product manuals