System Information Commands
Page 322 7750 SR OS Basic System Configuration Guide
Default no boot-good-exec
Parameters file-url — Specifies the location and name of the file executed following successful completion of the
boot-up configuration file execution. When this parameter is not specified, no CLI script file is
executed.
Values file url: local-url | remote-url: 255 chars max
local-url: [cflash-id/][file-path]
remote-url: [{ftp://} login:pswd@remote-locn/][file-path]
remote-locn [ hostname | ipv4-address | [ipv6- address] ]
ipv4-address a.b.c.d
ipv6-address - x:x:x:x:x:x:x:x[-interface]
x:x:x:x:x:x:d.d.d.d[-interface]
x - [0..FFFF]H
d - [0..255]D
interface - 32 chars max, for link local addresses
cflash-id: cf1:, cf1-A:,cf1-B:,cf2:,cf2-A:,cf2-B:,cf3:,cf3-A:,cf3-B:
Related
Commands
exec command on page 59 — This command executes the contents of a text file as if they were CLI
commands entered at the console.
chassis-mode
Syntax chassis-mode [chassis-mode] [force]
Context config>system
Description This command configures the chassis scaling and feature set.
Note that, if you are in chassis-mode d and configure an IOM type as iom2-20g and then downgrade
to chassis-mode a or b (must specify force keyword), a warning appears about the IOM downgrade.
In this case, the IOM`s provisioned type will downgrade to iom-20g-b. Once this is done, the ASAP
MDA cannot be configured.
The ASAP MDA can only be configured if the iom2-20g IOM type is provisioned and equipped and
the chassis mode is configured as a or b.
If this is the desired behavior, for example, chassis-mode d is configured and IPv6 is running, you can
then downgrade to chassis-mode a or b if you want to disable IPv6.
For chassis mode d, the default must be changed from the default mode a which assumes the least
available features. Mode d enables the new feature sets available with newer generations of IOMs.
Chassis mode d supports the P2/Q2/T2-based IOMs products and the extensive queuing/policing/
bandwidth. Mode d assumes that the iom3-xp is installed.
Default a
Parameters chassis-mode — Specify the one of the following chassis modes:
a: This mode corresponds to scaling and feature set associated with iom-20g.
b: This mode corresponds to scaling and feature set associated with iom-20g-b.
c: This mode corresponds to scaling and feature set associated with iom2-20g.