Chapter 8
Equipment Sequence
466 Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Available Languages
Ladder Diagram
Function Block
This language is not available for this instruction.
Structured Text:
SATT(SequenceName,Result)
Operands
The SATT instruction uses the following operands.
Operand Type Format Description
Sequence Name Sequence name of the Equipment
Sequence
Equipment Sequence that you want to change to
own (attach) to command (for example,
Make_Product_101).
Result DINT immediate
tag
To let the instruction return a code for its success
or failure, enter a DINT tag in which the result
code is stored. Otherwise, enter 0.
Affects Math Status Flags
No
Major/Minor Faults
The SATT instruction cannot trigger a fault, so there are no fault conditions for
this instruction.