Programming
115
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
Embedded Codes
The following is a list of G4 compatible embedded codes:
Panel Setup Commands
These commands are case insensitive.
Embedded Codes
Decimal numbers Hexidecimal values Virtual keystroke Decimal numbers Hexidecimal values Virtual keystroke
8 ($08) Backspace 146 ($92) Delete
13 ($0D) Enter 147 ($93) Home
27 ($1B) ESC 148 ($94) End
128 ($80) CTRL key down 149 ($95) Page Up
129 ($81) ALT key down 150 ($96) Page Down
130 ($82) Shift key down 151 ($97) Scroll Lock
131 ($83) F1 152 ($98) Pause
132 ($84) F2 153 ($99) Break
133 ($85) F3 154 ($9A) Print Screen
134 ($86) F4 155 ($9B) SYSRQ
135 ($87) F5 156 ($9C) Tab
136 ($88) F6 157 ($9D) Windows
137 ($89) F7 158 ($9E) Menu
138 ($8A) F8 159 ($9F) Up Arrow
139 ($8B) F9 160 ($A0) Down Arrow
140 ($8C) F10 161 ($A1) Left Arrow
141 ($8D) F11 162 ($A2) Right Arrow
142 ($8E) F12 192 ($C0) CTRL key up
143 ($8F) Num Lock 193 ($C1) ALT key up
144 ($90) Caps Lock 194 ($C2) Shift key up
145 ($91) Insert
Panel Setup Commands
@PWD Set the page flip password. @PWD sets the level 1 password only.
Syntax:
"'@PWD-<page flip password>'"
Variables:
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'@PWD-Main'"
Sets the page flip password to 'Main'.
^PWD Set the page flip password. Password level is required and must be 1 - 4.
Syntax:
"'^PWD-<password level>,<page flip password>'"
Variables:
password level = 1 - 4.
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^PWD-1,Main'"
Sets the page flip password on Password Level 1 to 'Main'.