3.2 Remote USB operation
You can control the Motherboard Configuration Controller (MCC) through the Debug USB port.
To enable remote USB operation, you must set the USB_REMOTE parameter in the config.txt file to:
TRUE to enable the remote USB feature.
FALSE to disable the feature.
You initiate a command by putting a file into the USBMSD root directory through the USB port. You can
reboot the system, reset the system, or shut down the system by using one of the following filenames:
reboot.txt.
reset.txt.
shutdown.txt.
The MCC detects the presence of the files, performs the requested command, and deletes the file.
Note
The contents of the files have no effect. They can be empty files.
Related information
1.3 Location of components on the MPS3 board on page 1-15
A.1.6 Debug USB 2.0 connector on page Appx-A-75
3 Configuration
3.2 Remote USB operation
100765_0000_04_en Copyright © 2017–2020 Arm Limited or its affiliates. All rights
reserved.