Testing the boiler and changing settings
Boiler Manual test setting
Select manual mode activation 2.6.0 and change from 0 = OFF to 1 = ON to enable manual testing mode.
Change parameter 2.6.1 to 2.6.7 component from 0 = OFF to 1 = ON to enable manual testing of the pump, fan, diverter
valve, additional output control or external pump control.
The setting are accessible through a code:
BACK OK
19°25/07/18 09:00
80°60°
ECO AUTO
Press OK to enter Menu
1.5 bar
Insert Code
007
Save
Insert technical code
Menu
0
1
2
3
4
Network
<Not Available>
Boiler Parameters
<Not Available>
Zone 1 Parameters
Boiler Parameters
2
2.2
2.3
2.4
2.5
2.6
Settings
Central Heating-1
Central Heating-2
Domestic Hot Water
Boiler manual settings
From the controller Home screen,
press the BACK and OK buttons
at the same time for 7 seconds
1
Turn the selector wheel to highlight 007
as the Technical Code. Press OK to Save.
2
Turn the selector wheel to highlight
2 Boiler Parameters. Press OK.
4
2.6 Manual settings.
6
Turn the selector wheel to highlight
2.6 Boiler manual setting. Press OK.
5
Technical area
Language, date and time
Complete Menu
Configuration Wizard
Service
Faults
The screen below then appears.
Turn the selector wheel to highlight
Complete Menu. Press OK. It takes
a while to load the menu.
3
2.6. Boiler manual settings Name Description Range Default
2.6.0 Manual mode activation To enable or disable manual mode 0 = OFF 1 = ON 0 - 1 0
2.6.1 Pump Control 0 = OFF 1 = ON 0 - 1 0
2.6.2 Fan Control 0 = OFF 1 = ON 0 - 1 0
2.6.3 Diverter valve control 0 = OFF 1 = ON 0 - 1 0
2.6.5 Additional output control 0 = OFF 1 = ON 0 - 1 0
2.6.7 External Pump 0 = OFF 1 = ON 0 - 1 0
Boiler manual settings
2.6
2.6.0
2.6.1
2.6.2
2.6.3
2.6.4
Manual mode activation
Boiler pump control
Fan control
Diverter valve control
<Not Available>
Boiler manual settings
2.6
2.6.3
2.6.4
2.6.5
2.6.6
2.6.7
Diverter valve control
<Not Available>
Additional Output Control
<Not Available>
External Pump control
30