SmartROC T45-10 4 Operation
26
4.1.3StartingtheDieselEngine
!
NOTE:Monitorthedisplayduringoperationofthemachine.
Condition
p
ThebatteryisolationswitchissettoON.
p
Noemergencystopisactivated.
1.
Turntheignitionkey(B)totheignitionpositiontoactivatethecontrolsystem.Wait
aboutoneminute.
2.
PresstheResetbuttoninthecabin.
è
Agreencirclearoundthestartbutton(C)showsthattheignitionisswitchedon.
!
NOTE:Ifthegreencircleflashes,thesystemisnotreadyfor
theenginetostart.Waituntilthegreencircleislitsteady.Ifit
continuestoflash,checkwhichsymbolsareshownonthe
displayandcorrecttheerror.
3.
Presstheescapebutton(A)toresetstartupmessages.
4.
Pressandholdthestartbutton(C)forthedieselengine.Releasethebuttonwhenthe
dieselenginestarts.
!
NOTE:Iftheenginefailstostart,stoptryingafter20secondsand
waitoneminutebeforetryingagain.
5.
Checkthehydraulicoiltemperature.Ifthehydraulicoiltemperatureisbelow20ºC
(68ºF),drillingdoesnotwork.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco SmartROC T45--10 and is the answer not in the manual?

Atlas Copco SmartROC T45--10 Specifications

General IconGeneral
BrandAtlas Copco
ModelSmartROC T45--10
CategoryDrill
LanguageEnglish

Related product manuals