SmartROC T45-10 4 Operation
29
Ifautomaticregenerationisblockedwhenthewarningisshown,themachinemustbe
movedtoasafeplacebeforeactivatingtheforcedregeneration.
Tomakeconditionsmorefavourablefortheregenerationtostart,idlingmodeisrecom
mended.
TimeRemaininguntilnextAutomaticRegeneration
TheremaininghoursuntilthenextautomaticregenerationisshowninmenuEngine.The
numberofhoursindicatedisanapproximation.Theregenerationprocesscanbestarted
severalhoursbeforethetimeshown.
BlockedAutomaticRegeneration
Automaticregenerationcanbeblockedtemporarily,forexample:
n Exhaustventingequipmentisfittedontheriginconnectionwithrepairs.
n Personnelneedtobeonthesuperstructureoftherigwiththedieselenginestarted.
n Vegetationorotherflammablematerialsareneartheexhaustgases.
Automaticregenerationcanonlybeblockedwhenthedieselengineisstarted.Blockedre
generationisautomaticallyresetwhentheignitionisswitchedoff/on.
AutomaticregenerationisblockedinmenuEngine.
ForcedRegeneration
Forcedregenerationcanonlybestartedwhenthereislessthaneighthoursremaininguntil
nextautomaticgeneration.
Aforcedregenerationcanbestartedfortworeasons:
n Thewarningsymbol isshowninthemenustatusbar.Whenthissymbolisshown
inthemenu,forcedregenerationmustbestarted.
n Themachinewillsoonbeworkinginalocationthatisnotsafeforregeneration,requir
ingaforcedregenerationtobeperformeddirectly.
4.1.6DelayedEngineShutdown
Whentheengineisswitchedoff,itmaycontinuetorunatidlingspeedforafewminutes.
Thedelayedengineshutdown(DES)timevariesbetween1and7minutes.
DESisintendedtoenablethedieselexhaustfluid(DEF)injectionsystemtocooldownbe
foretheenginestops.ThisreducestheriskofdamagetotheDEFinjector.
TestingEmergencyStopsonMachinesEquippedwithDEFinjectionsystem
Theemergencystopsystemshouldbetestedpriortoeachshiftbyactivatingeachemer
gencystopbutton.Iftheengineishot,thereisariskofdamagingtheDEFinjector.Insuch
cases,theenginemustberestartedimmediatelyaftereachemergencystopbuttonhas
beenpressed.