SmartROC T45-10 4 Operation
52
Checkpoint Inspection Instructions
Returnoilfilter Operator'sdisplayincabin Checkforanysignsofleaks.If
thepressureinthereturnoilfilter
exceedsthesetvalue,asymbol
willbeshownontheoperator's
display.
Displayforengineanddirec
tionalinstruments
Visualcheck Checkthatnoneofthefaultindi
catorsymbolsison.Ifafaultis
indicatedinthestatusbar,stop
theunitandrectifythefault.
Hydraulicsystem Visualcheck Monitorallpressuregaugesin
theDrillingmenu.
Suctionhood Occurrenceofcrushedrock Raisethesuctionhoodnowand
thentocheckthatcrushedrock
isflushedupproperlyfromthe
hole.
4.5.7InCaseofBreakdownorIncident
CheckingHighCouplingSleeveTemperature
!
NOTE:Couplingsleevetemperaturemustnotexceed120ºC(248ºF).
Dependingonthelayersoftherock,temperaturecanvaryevenwithinasmallarea.High
couplingsleevetemperatureisusuallyduetoapoorratiobetweendrillfeedpressure,per
cussionpressureandrotationpressure.
Excessivecouplingsleevetemperatureisindicatedby:
n Measuringwithathermometer.
n Oildrippingfromtherockdrillvaporizingonthecouplingsleeve.
n Thecouplingsleevechangingcolor.
ReducingCouplingSleeveTemperature
1.
Checktheconditionofthedrillbit.Anoverdrilledbitgenerateslesstorqueinthecou
plingsleeve.
2.
Grindthedrillbit.
3.
Changetoadrillbitwithballisticbuttons.
4.
Reducerotationspeedasmuchaspossiblewithoutcausingthedrillstringtorotate
jerkilyIftherockistoohardforballisticbits.
5.
Checkthedampeningpressureandsetittotherecommendedlevel.Reducepercus
sionpressuretobelowthebasicsetting(510bar).Areasonablereductioninpene
trationratemustbeaccepted.
6.
Checkand/oradjustfeedpressuresothattheshankadapterisin“floatposition”.