SmartROC T45-10 4 Operation
52
Checkpoint Inspection Instructions
Returnoilfilter Operator'sdisplayincabin Checkforanysignsofleaks.If
thepressureinthereturnoilfilter
exceedsthesetvalue,asymbol
willbeshownontheoperator's
display.
Displayforengineanddirec
tionalinstruments
Visualcheck Checkthatnoneofthefaultindi
catorsymbolsison.Ifafaultis
indicatedinthestatusbar,stop
theunitandrectifythefault.
Hydraulicsystem Visualcheck Monitorallpressuregaugesin
theDrillingmenu.
Suctionhood Occurrenceofcrushedrock Raisethesuctionhoodnowand
thentocheckthatcrushedrock
isflushedupproperlyfromthe
hole.
4.5.7InCaseofBreakdownorIncident
CheckingHighCouplingSleeveTemperature
!
NOTE:Couplingsleevetemperaturemustnotexceed120ºC(248ºF).
Dependingonthelayersoftherock,temperaturecanvaryevenwithinasmallarea.High
couplingsleevetemperatureisusuallyduetoapoorratiobetweendrillfeedpressure,per
cussionpressureandrotationpressure.
Excessivecouplingsleevetemperatureisindicatedby:
n Measuringwithathermometer.
n Oildrippingfromtherockdrillvaporizingonthecouplingsleeve.
n Thecouplingsleevechangingcolor.
ReducingCouplingSleeveTemperature
1.
Checktheconditionofthedrillbit.Anoverdrilledbitgenerateslesstorqueinthecou
plingsleeve.
2.
Grindthedrillbit.
3.
Changetoadrillbitwithballisticbuttons.
4.
Reducerotationspeedasmuchaspossiblewithoutcausingthedrillstringtorotate
jerkilyIftherockistoohardforballisticbits.
5.
Checkthedampeningpressureandsetittotherecommendedlevel.Reducepercus
sionpressuretobelowthebasicsetting(510bar).Areasonablereductioninpene
trationratemustbeaccepted.
6.
Checkand/oradjustfeedpressuresothattheshankadapterisin“floatposition”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco SmartROC T45--10 and is the answer not in the manual?

Atlas Copco SmartROC T45--10 Specifications

General IconGeneral
BrandAtlas Copco
ModelSmartROC T45--10
CategoryDrill
LanguageEnglish

Related product manuals