MP-1xx SIP
MP-1xx SIP User’s Manual 108 Document #: LTRT-65404
Trap Port
[SNMPManagerTrapPort_x]
Up to five parameters used to define the Port numbers of the remote SNMP
Managers. The device sends SNMP traps to these ports.
Note: The first entry (out of the five) replaces the obsolete parameter
SNMPTrapPort.
The default SNMP trap port is 162
The SNMP trap port must be between 100 to 4000.
Trap Enable
[SNMPManagerTrapSendingEnable_x]
Up to five parameters, each determines the activation/deactivation of sending
traps to the corresponding SNMP Manager.
Disable [0] = Sending is disabled
Enable [1] = Sending is enabled (default)
Table 5-29 describes the board parameters that can only be configured via the ini file.
Table
5-29: Board, ini File Parameters (continues on pages 108 to 110)
ini File Parameter Name Valid Range and Description
LifeLineType
The Lifeline is activated on:
0 = Power down (default)
1 = Power down or when link is down (physical disconnect)
2 = Power down or when link is down or on network failure (logical link
disconnect)
Note: To enable Lifeline switching on network failure, LAN watch dog must be
activated (EnableLANWatchDog=1).
DSPVersionTemplateNumber
0 = Firmware DSP version supports PCM/ADPCM, G723 and G729A Coders
(default).
1 = Firmware DSP version supports PCM/ADPCM.
2 = Same as "0" but with voice and energy detectors.
3 = Same as "1" but with voice and energy detectors.
Usually DSP templates 2 or 3 should be used. These templates are required
for the FXO gateway Answer and Disconnect supervision features.
EnableDiagnostics
0 = No diagnostics (default).
1 = Perform diagnostics.
WatchDogStatus
0 = Disable gateway’s watch dog.
1 = Enable gateway’s watch dog (default).
DisableRS232
0 = RS-232 serial port is enabled (default)
1 = RS-232 serial port is disabled
To enable sending of all log and error messages to the RS-232 serial port,
define:
“EnableSyslog = 0” and “DisableRS232 = 0”
DisableWebTask
0 = Enable Web management (default)
1 = Disable Web management
ResetWebPassword
Enables resetting to default of Web password to:
Username: “Admin”
Password: “Admin”
DisableWebConfig
0 = Enable changing parameters from Web (default)
1 = Operate Web server in “read only” mode
HTTPport
HTTP port used for Web management (default = 80)
EthernetPhyConfiguration
0 = 10 Base-T half-duplex.
1 = 10 Base-T full-duplex.
2 = 100 Base-TX half-duplex.
3 = 100 Base-TX full-duplex.
4 = Auto-Negotiate (Default).
Note: Auto-Negotiate falls back to half-duplex mode (HD) when the opposite
port is not in auto-negotiate, but the speed (10 Base-T, 100 Base -TX) in this
mode is always configured correctly.

Table of Contents

Other manuals for AudioCodes MP-104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-104 and is the answer not in the manual?

AudioCodes MP-104 Specifications

General IconGeneral
BrandAudioCodes
ModelMP-104
CategoryGateway
LanguageEnglish

Related product manuals