MP-1xx SIP
MP-1xx SIP User’s Manual 172 Document #: LTRT-65404
Figure 9-2: Setting the Syslog Server IP Address
• Alternately, use the Embedded Web Server or the BootP/TFTP utility to load the ini
configuration file containing both the IP address and the enabling parameters:
SyslogServerIP and EnableSyslog respectively. For detailed information on the BootP/TFTP
utility, refer to
Appendix B on page 197. For an ini file example showing these parameters,
refer to Section 9.3.2.3 and to Figure 9-2 under it.
9.3.2.3 The ini File Example for Syslog
Figure 9-2 shows an ini file section with an example configuration for the address parameter
SyslogServerIP and an example configuration for the client activation parameter EnableSyslog.
Figure
9-3: The ini File Example for Syslog
[Syslog]
SyslogServerIP = 10.2.0.136
EnableSyslog = 1
GWDebugLevel = 5
9.4 Solutions to Possible Problems
9.4.1 General
If there is a problem, check the following resources:
• The ‘Channel Status’ pages on the Web Interface. Refer to Section
5.10 on page 124.
• The Log Message on the Web Interface, refer to Section
5.10.3 on page 129.
• Log messages sent to the RS-232 Port. Refer to Section
9.2 on page 170.
• BootP & TFTP log messages (for startup problems). Refer to Section
B.9 on page 200.
• Log messages in Syslog server. Refer to Section
9.2.2 on page 170.