8-7-10. Monitor Function of Remote Controller Switch
When using a remote controller with the model name RBC-AMT32UL, the following monitor
functions can be used.
Calling of display screen
<Content>
The sensor temperature or operation status of the remote controller, indoor unit, or the outdoor unit can be
known by calling up the service monitor mode from the remote controller.
[Procedure]
1 Push + buttons simultaneously for 4 seconds or more to call up the service monitor
mode.
The service monitor goes on, and temperature of the CODE No. 00 is firstly displayed.
2 Push the temperature setup buttons to select the CODE No. to be monitored.
For displayed codes, refer to the table next page.
3 Push button to determine the item to be monitored.
Then monitor the sensor temperature or operation status of indoor unit and the outdoor unit in the
corresponding refrigerant line.
4 Pushing button returns the display to the normal display.
SET
TIME
TIMER SET
TEST
FILTER
RESET
TEMP.
CL
FAN
SAVE
SWING/FIX
VENT
MODE
ON / OFF
UNIT LOUVER
1
4
2
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier RBM-Y0613FUL and is the answer not in the manual?

Carrier RBM-Y0613FUL Specifications

General IconGeneral
BrandCarrier
ModelRBM-Y0613FUL
CategoryAir Conditioner
LanguageEnglish

Related product manuals