chapter 5000
page 66
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
PROGRAMMED LEVEL
PARAMETER
UNIT 0 1 2 3 4 5 6 7 8 9
ACCELERATION DELAY (*) SEC 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5
RELEASE BRAKING (**) SEC 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
INVERS BRAKING (**) SEC 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
PEDAL BRAKING (**) SEC 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
SPEED LIMIT BRAKING (**) SEC 8.9 8.3 7.7 7.1 6.6 6.0 5.5 4.9 4.4 3.8
BRAKE CUTBACK (**) SEC 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0
MAX SPEED FW HZ 65 80 95 110 125 140 155 170 185 200
MAX SPEED BW HZ 65 80 95 110 125 140 155 170 185 200
CURVE CUTBACK % 10 20 30 40 50 60 70 80 90 100
CUTBACK SPEED % MAX SPEED 10 20 30 40 50 60 70 80 90 100
FREQUENCY CREEP HZ 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0
MAXIMUM CURRENT % IMAX 47 53 58 64 70 76 82 88 94 100
ACC. SMOOTH
INV. SMOOTH
STOP SMOOTH HZ
AUXILIARY TIME SEC 0 0.2 0.4 0.8 1 1.5 2 3 4 5
(*) The acceleration time shown is the time from 0 Hz to 100 Hz. This is the ideal ramp calculated by the
software; the real ramp could change according to the motor parameters setting and, obviously, according
to the load.
(**) The braking feature is based upon deceleration ramps. The value shown in the table is the time to
decrease the speed from 100 Hz to 0 Hz. This is the ideal ramp calculated by the software; the real ramp
could change according to the motor parameters setting and, obviously, according to the load.
DUAL AC2 TRACTION UNIT