chapter 5000
page 34
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
ACCELERATOR POTENTIOMETER CONFIGURATION
Values optained by the multimeter
Yellow : 1,2 V
Green : 0,2 ÷1,2 V with pedal pressed
Black : 0,2 V
The test of the potentiometer can be carried out in two different ways:
Values optained by the console
Yellow : 1,6 V
Green : 0,6 ÷1,6 V with pedal pressed
Black : 0,6 V
There is a difference between the values obtained in the two methods because, in case of voltage
measurement, the console increases the real value of 0.4 volt and it is a default condition
SINGLE PEDAL VERSIONDOUBLE PEDAL VERSION
)
4,5 KOhm
1,2 KOhm
ç
Yellow
Green
Red
)
)
Yellow
Green
Black