Attach an ESD-preventive wrist strap to your wrist and connect the other end to the grounding lug
connected to the chassis.
Remove the Power Modules.
If you are replacing the entire power system, remove the Power Cassette Module.
Be aware of the weight and size of the equipment. Handle it with care.
Required Tools and Equipment
ESD-preventive wrist strap
T10 Torx screwdriver
Antistatic bag
Step 1 Loosen and remove the four #6-32 Torx-head screws on the mounting flanges of the FPEM using a T10 Torx screwdriver.
Figure 120: Removing the FPEM from the Chassis
Step 2 Slide the FPEM out of the chassis using the handles on either side applying even pressure to both handles.
Step 3 Place the removed FPEM in an antistatic bag.
Cisco Converged Broadband Routers Hardware Installation Guide
194
Maintaining the Power System in the Cisco cBR Chassis
Removing the FPEM from the Cisco cBR Chassis