EasyManuals Logo

Daikin Altherma HT Service Manual

Daikin Altherma HT
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #210 background imageLoading...
Page #210 background image
Troubleshooting by Indication on the Remote Controller ESIE09-08B
198 Troubleshooting
3.55 “U2 Power Supply Insufficient or Instantaneous Failure
Remote Control
Display
U2
Subcode 20: high/low voltage problem
Subcode 21: converter problem
Applicable
Models
All indoor units
Method of
Malfunction
Detection
Detection of voltage of main circuit capacitor built in the inverter and power supply voltage.
Malfunction
Decision
Conditions
When the abnormal voltage of main circuit capacitor built in the inverter and abnormal power
supply voltage are detected.
Supposed
Causes
Power supply insufficient
Instantaneous power failure
Defect of indoor inverter PC board [A4P (1
ø) or A5P (3ø)]
Converting problem
Warning: CAPACITOR SHOCK HAZARD. The capacitors (top surfaces) can hold up to
220V. Use correct precautions when servicing.

Table of Contents

Other manuals for Daikin Altherma HT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma HT and is the answer not in the manual?

Daikin Altherma HT Specifications

General IconGeneral
TypeAir-to-water heat pump
RefrigerantR-410A
Water Outlet TemperatureUp to 80°C
Operating Temperature Range-20°C to 35°C
Power Supply3-phase, 400V
Energy Efficiency Class (Heating)A++

Related product manuals