3.4 Enclosure Size Identication
Enclosure size is used throughout this guide whenever
procedures or components dier between drives based on
physical size. This service guide includes the enclosure
sizes listed in Table 3.3.
Enclosure size Power rating
D1h–D8h drives 90–400 kW
E1h–E4h drives 315–710 kW
J8–J9 drives 90–315 kW
Da2/Db2/Da4/Db4 parallel drive systems 250–1200 kW
Drives modules in D9h–D10h and E5h–E6h
enclosed drive systems
315–800 kW
Table 3.3 Enclosure Size Overview
Find the enclosure size using the following steps:
1. Locate the nameplate label:
1a In parallel drive systems, the label is
found on the control shelf to the lower
right of the local control panel (LCP).
See Illustration 3.5.
1b For drives in enclosure sizes D1h-D8h,
E1h-E4h and J8-J9, the label is found
inside the drive enclosure.
2. Obtain the following information from the type
code on the nameplate. Refer to Illustration 3.1.
2a Product group and drive series
(characters 1–6)
2b Power rating (characters 7–10)
2c Voltage rating (phases and mains)
(characters 11–12)
2d Type of drive (character 16). If the
character “P” is shown, note character
17 as well.
3. Find the appropriate voltage rating table for the
product group and drive series. Refer to
chapter 3.5 Enclosure Size Denitions. For example,
T4 for FC 102 and FC 202.
4. Within the table, nd the power rating and look
up the type of drive.
130BF045.10
OUT: 3x0-Vin 0-590Hz 260/240A
IN: 3x380-500V 50/60Hz 251/231A
132 kW/200 HP, High Overload
OUT: 3x0-Vin 0-590Hz 315/302A
IN: 3x380-500V 50/60Hz 304/291A
160 kW/250 HP, Normal Overload
VLT
P/N: 134X5584 S/N: 000201H345
CAUTION:
Stored charge, wait 30 min.
Charge residuelle, attendez 30
See manual for special condition/ mains fuse
Voir manuel de conditions speciales/fusibles
WARNING:
R
AutomationDrive
www.danfoss.com
`
`
3
21
4
T/C: FC-302N132T5E20H2BGR7XXSXXXXAXBKCXRXXD0
5
CHASSIS/IP20
Tamb. 45 C/113 F at Full Output Current
Max Tamb. 55 C/131 F w/ Output Current Derating
SCCR 100 kA at UL Voltage range 380-500V
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
OUT: 3x0-Vin 0-590Hz 1260/1160 A
IN: 3x380-500V 50/60Hz 1227/1129 A
710 kW / 1000 HP, High Overload
OUT: 3x0-Vin 0-590Hz 1460/1380 A
IN: 3x380-500V 50/60Hz 1422/1344 A
800 kW / 1200 HP, Normal Overload
VLT
T/C: FC-302N710T5E00P2BGC7XXSXXXXAXBXCXXXXDX
P/N: 134X4109 S/N:
R
AutomationDrive
www.danfoss.com
ASSEMBLED IN USA
CAUTION - ATTENTION:
Stored charge, wait 20 min.
Charge residuelle, attendez 20
See manual for special condition / prefuses
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
`
`
Tamb. 45
˚
C/113
˚
F at Full Output Current
CHASSIS (OPEN TYPE) / IP00
SCCR 100 kA at UL Voltage range 380-500 V
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
Max. Tamb. 55
˚
C/131
˚
F w/ Output Current Derating
123456H123
3
21
4
5
1 Product group and drive series
2 Power rating
3 Voltage rating (phases and mains)
4
Drive type:
H = 6-pulse drive
P2 = 6-pulse, class A2 RFI
P4 = 6-pulse, class A1 RFI
P6 = 12-pulse, class A2 RFI
P8 = 12-pulse, class A1 RFI
5
Build date (wwy, where ww = the week and y = last digit
of the year). For example, 345 = week 34 of 2015.
Illustration 3.1 Sample Nameplates
Product Overview
VLT
®
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9
16 Danfoss A/S © 02/2019 All rights reserved. MG94A502
33