13.2.24 Top Fan
To remove or reinstall the top fan, use the following steps. Refer to Illustration 13.30.
Disassembly
1. Remove 2 screws (T25) from the fan housing.
2. Slide the fan housing and fans out from under
the retaining clips.
3. Unplug the in-line connector attaching the fan
cable. Feed the cable through the cable access
hole.
4. Lift the fans from the pins in the fan housing.
Reassembly
Tighten fasteners according to chapter 14.1 Fastener Torque
Ratings.
1. Place the fans over the pins in the fan housing,
with the fan arrows pointing away from the drive.
2. Feed the fan cables through the cable access hole
on the top plate.
3. Reconnect the in-line cable connector.
4. Slide the fan housing and fans into position
under the retaining clips.
5. Secure 2 screws (T25) in the fan housing.
E1h–E4h Drive Disassembly a... Service Guide
MG94A502 Danfoss A/S © 02/2019 All rights reserved. 309
13 13