4.1.2 Setting LCP Display Values
The display area is activated when the frequency converter
receives power from mains
voltage, or an external 24 V
supply.
The information displayed on the LCP can be customized
for user application.
Each display readout has a parameter associated
with it.
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable. See 6.3 Status Message Definitions
Table for more information.
Display Parameter number Default setting
1.1 0-20 Motor RPMs
1.2 0-21 Motor current
1.3 0-22 Motor power (kW)
2 0-23 Motor frequency
3 0-24 Reference in percent
130BC363.10
1.1
3
1.3
799 RPM
Auto Remote Ramping
1 (1)
0.75 kW0.98 A
0.000
53.2 %
Status
1.2
2
1.2
2
207RPM
Auto Remote Running
1 (1)
0.75 kW
0.98 A
6.9
Hz
Status
130BC364.10
1.1
1.3
4.1.3 Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display
modes during normal
operation, and viewing fault log data.
130BP045.10
Status
Quick
Menu
Main
Menu
Alarm
Log
Key Function
Status Shows operational information.
In
Auto mode, press
to toggle between
status read-out displays
Press repeatedly to scroll through each
status display
Press [Status] plus [
] or [
] to adjust the
display brightness
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu Allows access to programming parameters for
initial set up instructions
and many detailed
application instructions.
Press to access Q2 Quick Setup for
sequenced instructions to program the basic
frequency controller set up
Follow the sequence of parameters as
presented for the function set up
Main Menu Allows access to all programming parameters.
Press twice to access
top-level index
Press once to return to the last location
accessed
Press to enter a parameter number for
direct access to that parameter
Alarm Log Displays a list of current warnings, the last 10
alarms, and the maintenance
log.
For details about the frequency converter
before it entered the alarm mode, select the
alarm number using the navigation keys
and press [OK].
User Interface
VLT
®
Decentral Drive FCD 302 Operating Instructions
34 MG04F302 - VLT
®
is a registered Danfoss trademark
44
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Danfoss vlt fcd 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt fcd 302 and is the answer not in the manual?

Danfoss vlt fcd 302 Specifications

General IconGeneral
BrandDanfoss
Modelvlt fcd 302
CategoryController
LanguageEnglish

Related product manuals