Area Title Functions
7 Output to
motor
By controlling the voltage and frequency,
the
frequency converter provides
regulated
motor control from 0-50/60 Hz at 100%
supply voltage.
Area Title Functions
8 Control
circuitry
Input
power, internal processing,
output,
and motor current are monitored to
provide efficient operation and control
User interface and external commands
are monitored and performed
Status output and control can be
provided
Table 1.1 Frequency Converter Internal Components
1.7 Type Code Description
Position 2 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 39 39
F C D 3 0 2 P T 4 H 1 X A B X X X X X D
1 3 5
130BB797.10
Position Description Choices/options
01-03 Product group FCD Decentral Drive
04-06
Frequency
converter series
302 Advanced performance
07-10 Power
size
PK37 0.37 kW/0.5 HP
PK55 0.55 kW/0.75 HP
PK75 0.75 kW/1.0 HP
P1K1 1.1 kW/1.5 HP
P1K5 1.5 kW/2.0 HP
P2K2 2.2 kW/3.0 HP
P3K0
3.0 kW/4.0 HP (large unit
only)
PXXX
Installation box only
(without
power section)
11-12
Phases, Mains
voltage
T
Three phase
4 380-480 V AC
13-15 Enclosure
B66
Standard Black -
IP66/Type 4X
W66
Standard White -
IP66/Type 4X
W69
Hygienic White -
IP66K/Type
4X
16-17 RFI filter H1
RFI filter class A1/C2
18 Brake
X No brake
S
Brake chopper +
mechanical
brake Supply
Position Description Choices/options
19
Hardware
configuration
1
Complete product, small
unit,
stand alone mount
3
Complete product, large
unit, stand alone mount
X
Drive
part, small unit (No
installation box)
Y
Drive part, large
unit (No
installation box)
R
Installation box, small
unit,
stand alone mount (No
drive
part)
T
Installation box, large unit,
stand alone mount (No
drive
part)
20 Brackets
X No brackets
E Flat brackets
F 40 mm brackets
21 Threads
X No installation box
M Metric threads
22 Switch option
X No switch option
E
Service switch on mains
input
F
Service switch on motor
output
H
Circuit breaker & mains
disconnect,
looping
terminals (large unit
only)
K
Service switch on mains
input with additional
looping terminals
(large
unit only)
23 Display
X
No display connector (No
installation box)
C With Display
Connector
Introduction
VLT
®
Decentral Drive FCD 302 Operating Instructions
MG04F302 - VLT
®
is a registered Danfoss trademark
7
1 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Danfoss vlt fcd 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt fcd 302 and is the answer not in the manual?

Danfoss vlt fcd 302 Specifications

General IconGeneral
BrandDanfoss
Modelvlt fcd 302
CategoryController
LanguageEnglish