Chapter 3 Interface Introduction
3-13
3_
3.2.1 Load Cell Setup
Press the key to display the corresponding setting page of the Load Cell Setup.
There are 10 setting items for you to set up.
(1) Excitation Voltage: set up the excitation voltage at the load cell, ranging from 2.0 V to 9.5 V.
(2) Eigenvalue Mode: set up the eigenvalue mode from 0 to 9; the excitation voltage in different eigenvalue modes
corresponds to different eigenvalues. See the table below for reference.
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
9.5
0
0.5
8.0
0
0.5
6.0
0
0.5
3.5
0
0.5
1
1
1
1
1
1
1
1
2 2 2 2 2 2 2 2
3 3 3 4 3 4 3 4
4
4
4
8
4
8
4
8
5
6
5
16
5
16
5
16
6
7
6
32
6
32
6
32
7 10 7 50 7 64 7 64
8 12 8 75 8 128 8 128
9
16
9
100
9
256
9
256
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
Excitation
voltage
Eigenvalue
modes
Eigenvalue
(mV/V)
9.0
0 0.5
7.0
0 0.5
5.0
0 0.5
2.0
0 0.5
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
4
3
4
3
4
3
4
4 8 4 8 4 8 4 8
5 12 5 16 5 16 5 16
6
16
6
32
6
32
6
32
7
24
7
64
7
64
7
64