139
11 API Frame Type (Explicit Frame)
01 Frame Identifier (for response matching)
0000000000000000 Coordinator address
fffe Code for unknown network address
00 Source Endpoint (need not be 0x00)
00 Destination Endpoint (ZDO endpoint)
0020 Cluster 0x0020 (End_Device_Bind_req)
0000 ProfileID (ZDO)
00 Radius (default, maximum hops)
00 Transmit Options
01f2995cb5474000a21300e605c1010100010200 RFData (ZDO payload)
46 Checksum
Here is the RFData (the ZDO payload) broken into labeled fields. Note the multi-byte fields of a ZDO
payload are represented in little-endian format.
01 Transaction Sequence Number
f299 Binding Target (16 bit network address of sending device)
5cb5474000a21300 (64 bit address of sending device)
e6 Source Endpoint on sending device
05c1 ProfileID (0xC105) - used when matching End_Device_Bind_requests
01 Number of input clusters
0100 Input cluster ID list (0x0100)
01 Number of output clusters
0200 Output cluster ID list (0x0200)
Example of a End_Device_Bind_req
Bind_req
The Bind request (ZDO cluster 0x0021) is described in the Zigbee Specification. A binding may be coded
for either a unicast or a multicast/groupID message.
Unbind_req
The Unbind request (ZDO cluster 0x0022) is described in the Zigbee Specification.