AT commands Command mode options
Digi XBe 3 Zigbe RF Module
205
Parameter Description
4 Digital output, low
5 Digital output, high
Default
1
Command mode options
The following commands affect how Command mode operates.
CN (Exit Command mode)
Executable command. CN immediately exits Command mode and applies pending changes.
Parameter range
N/A
Default
N/A
CT (Command Mode Timeout)
Sets or displays the Command mode timeout parameter. If the local device enters Command mode
and does not receive any valid AT commands within this time period, Command mode silently exits.
Parameter range
2 - 0x28F
Default
0x64 (10 seconds)
GT (Guard Times)
Set the required period of silence before and after the command sequence characters of the
Command mode sequence, GT + CC + GT (including spaces). The period of silence prevents
inadvertently entering Command mode if a data stream in Transparent mode includes the CC
character. For more information, see Enter Command mode.
Parameter range
0x2 - 0xCE4 (x 1 ms)
Default
0x3E8 (one second)
CC (Command Character)
Sets or displays the character value used to break from data mode to Command mode. . The
command character must be sent three times in succession while observing the minimum guard time