AT commands Zigbee addressing commands
Digi XBee® 3 Zigbee® RF Module
195
When operating in API mode, if the Transmit Options field in the API frame is 0, the TO parameter
value will be used instead.
Parameter range
0 - 0xFF
Bit field:
Unused bits must be set to 0. These bits may be logically ORed together:
Bit Meaning
0 Disabled retries and route repair.
4 Secure Session. Send data securely—requires secure session.
5
Enable APS end-to-end encryption (if EE = 1).
6 Use extended timeout.
Default
0
SE (Source Endpoint)
Sets or displays the application layer source endpoint value used for data transmissions.
This command only affects outgoing transmissions in Transparent mode (AP = 0).
Note Endpoints 0xDC - 0xEE are reserved for special use by Digi and should not be used in an
application outside of the listed purpose. The reserved Digi endpoints are:
n 0xE8 - Digi data endpoint
n 0xE6 - Digi device object endpoint
n 0xE5 - Secure Session Server endpoint
n 0xE4 - Secure Session Client endpoint
n 0xE3 - Secure Session SRP authentication endpoint
Parameter range
0 - 0xFF
Default
0xE8
DE (Destination Endpoint)
Sets or displays the application layer destination endpoint used for data transmissions.
This command only affects outgoing transmissions in Transparent mode (AP = 0).
Note Endpoints 0xDC - 0xEE are reserved for special use by Digi and should not be used in an
application outside of the listed purpose. The reserved Digi endpoints are: