AT commands Zigbee addressing commands
Digi XBe 3 Zigbe RF Module
194
Parameter range
0x20 - 0xFF (x 100 ms)
Default
0x3C (6 seconds)
NO (Network Discovery Options)
A bitfield that contains advanced network discovery options that do not have dedicated AT commands.
These options only affect the behavior of the local device when you issue an ND command or when
sending a node identification.
Parameter range
0 - 3
Option Description
0
Append the DD (Digi Device Identifier) value to ND responses and node identification
frames.
1
Local device sends ND response when the ND is issued.
Default
0x0
NP (Maximum Packet Payload Bytes)
Reads the maximum number of RF payload bytes that you can send in a transmission based on
current parameter settings.
Using APS encryption (API transmit option bit enabled), reduces the maximum payload size by 9 bytes.
Using source routing (AR < 0xFF), further reduces the maximum payload size depending on how many
hops are traversed.
Note NP returns a hexadecimal value. For example, if NP returns 0x54, this is equivalent to 84 bytes.
Parameter range
[read-only]
Default
N/A
Zigbee addressing commands
The following AT commands adjust the advanced communication settings that affect outgoing data
transmissions.
TO (Transmit Options)
The bitfield that configures the advanced options used for outgoing data transmissions for a device
operating in transparent mode (AP=0).