Emerson Process Management GmbH & Co. OHG 3-29
X-STREAM Non-Incendive
Instruction Manual
HASXENE-IM-EX
12/2014
3
Startup
3.11 Web Browser
IP address for Ethernet2 connector
To directly gain access to the instrument´s web
browser interface, rst ensure the instrument
is powered. Next connect it to the computer's
network adapter via Ethernet2 connector (see
Fig. 3-6) by means of an Ethernet cross-over
cable. Standard Ethernet cables do NOT
support direct connections!
For Ethernet2 connector set "Use DHCP"
to No (see gure to the left).
Depending on settings possibly carried out
earlier, the analyzer may now show an IP (see
gure to the left). If so, setup your computer's
IP the same way, only differing in the last
group (here e.g. to 123.456.78.10).
Alternatively you may use the analyzer's xed
IP, that is not shown on any menu page and
is accessible via Ethernet2 only:
The analyzer is now assigned the IP
192.168.1.88.
• Con gure your computer's IP to meet the
same net (192.168.1.) and assign a new
IP (e. g. 192.168.1.10). Do not use the
same IP as is assigned to the analyzer.
3.10.2 Connection to single computer
Con guring an IP Address for Computers Running Microsoft Windows
• To con gure your computer you need an administrator account!
Go to Start > Control Panel > Network Connections
Right-click on your LAN connection and click "Properties"
Under the heading "This connection uses the following items", click "Internet Protocol (TCP/IP)"
• Click "Properties"
A new window should pop up, click "Alternate Con guration"
Click "User Con gured" radio button
Setup the IP Address as 192.168.1.10, Subnet Mask as 255.255.255.0 and Default Gateway as 192.168.1.1.
• Click "OK"
Click "Close" in "LAN connection properties".
On your computer open a web browser and
enter the instrument´s IP address. If everything
is con gured properly, the analyzer's logon
screen shows up ( next page ).
Ethernet2
MAC 123456789
IP: 123.456.78.9
Subnet: 255.255.255.1
Gateway: 123.456.78.0
Use DHCP: No
IP Status Ready
Apply Con guration!
Setup..
Communcation..
Ethernet2..
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
u
r
at
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
i
io
io
o
io
o
o
o
o
o
o
o
io
o
i
i
i
i
i
n!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson X-STREAM Series and is the answer not in the manual?

Emerson X-STREAM Series Specifications

General IconGeneral
BrandEmerson
ModelX-STREAM Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals