E045 11 732786 - Rev.C
ENGLISH
4.6 J10 - BUS-2EASY ACCESSORIES
This board features a
BUS-2EASY
circuit for facilitating connection to the safety devices of a high
number of auxiliary
BUS-2EASY (MAX 16 pairs of photocells), encoder and control devices.
If no BUS-2EASY accessories are used, leave the BUS-2EASY connector free.
BUS-2EASY photocells
Before connecting the photocells, arrange them for the duly address assignment, depending on their
position and operation mode:
Photocells during closing:
trip only during the
closing of the automated system
- suitable for
protecting the closing area from risk of impact.
Photocells during opening:
trip only during the
opening of the automated system
- suitable for
protecting the opening area from risk of impact.
Photocells during opening/closing:
trip during
both the opening and closing
- suitable for protec-
ting the entire movement area from risk of impact.
Pulse generators: used as pulse generators for
opening the automated system
.
Closing
safety devices
Opening
safety devices
Opening/clo-
sing safety
devices
Should use of traditional photocells be required, you must use a BUS Interface Module
to be connected to the
BUS-2EASY J10 terminal.