139
EN
TransTig
2500 / 3000 Job
MV
Weight 24.2 kg
53.35 lb.
24.2 kg
53.35 lb.
Mark of conformity S, CE S, CE
TT 2500 Job TT 3000 Job
TT 2500 Job MV TT 3000 Job MV
Mains voltage 3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
Mains voltage tolerance ± 10 % ± 10 %
Mains frequency 50/60 Hz 50/60 Hz
Mains fuse protection (slow-blow)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
16 A
32 A
32 A
16 A
32 A
32 A
Mains connection
1)
Z
max
at PCC
3)
= 172 mOhm
Z
max
at PCC
3)
= 97 mOhm
Primary continuous power (100% d.c.
2)
)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
4.7 kVA
4.1 kVA
4.3 kVA
5.9 kVA
5.0 kVA
4.3 kVA
Cos phi 0,99 0,99
Welding current range (3-phase)
TIG 3 - 250 A 3 - 300 A
Electrode 10 - 250 A 10 - 300 A
Welding current range (single phase)
TIG 3 - 220 A 3 - 220 A
Electrode 10 - 180 A 10 - 180 A
Welding current at 3 x 400 - 460 V
10 min/40 °C (104 °F) 45% d.c.
2)
- 300 A
10 min/40 °C (104 °F) 50% d.c.
2)
250 A -
10 min/40 °C (104 °F) 100% d.c.
2)
200 A 240 A
Welding current at 3 x 200 - 240 V
10 min/40 °C (104 °F) 35% d.c.
2)
- 300 A
10 min/40 °C (104 °F) 40% d.c.
2)
250 A -
10 min/40 °C (104 °F) 100% d.c.
2)
180 A 210 A
Welding current at 1 x 200 - 240 V
10 min/40 °C (104 °F) 50% d.c.
2)
220 A -
10 min/40 °C (104 °F) 55% d.c.
2)
- 220 A
10 min/40 °C (104 °F) 100% d.c.
2)
190 A 190 A
Open circuit voltage 85 V 85 V
Working voltage
TIG 10.1 - 20.0 V 10.1 - 22.0 V
Electrode 20.4 - 30.0 V 20.4 - 32.0 V
Striking voltage (U
p
) 10 kV 10 kV
The arc striking voltage is suitable for manual operation.