6.2 FACTORY TEST
6-22
4. The “FACTORY TEST” screen is displayed.
The checking items of the SIO are switched in sequence. If a port jumpered in Step 1
functions properly, “OK” is displayed. If not, “—” is displayed.
Table 6.2.3 Result in Loopback Test
Test
item
Result
Test
speed
Description
AIS OK / -
38.4
kbps
Loopback test of AIS port J611. In the test, characters of
“FAR2107” are sent. If they are received, it is judged as OK.
HDG OK / -
38.4
kbps
Characters of “FAR2107” are sent from the SERIAL I/F (TD)
J621 to the HDG port J605. If they are received, it is judged as
OK.
LOG OK / -
38.4
kbps
Characters of “FAR2107” are sent from the J621: SERIAL I/F
(TD) to the J607: LOG port.
NAV OK / -
38.4
kbps
Characters of “FAR2107” are sent from J619: ECDIS (TD) to
J606: NAVIGATOR. If they are received, it is judged as OK.
TRK OK / -
38.4
kbps
Loopback test of TRK port. In the test, characters of “AR2107F”
are sent. If they are received, it is judged as OK.
RS-232C OK / -
4.8
kbps
Loopback test of J601: RS-232C. In the test, characters of
“FAR2107” are sent. If they are received, it is judged as OK.
KEY IO OK / -
19.2
kbps
The command of the test mode is sent to the control unit. If the
program number comes back, it is judged as OK.
RF IO OK / -
115.2
kbps
The command of the test mode is sent. If the program number
comes back, it is judged as OK.
ALARM
IO
1000->
0100->
0010->
0001
―
During the test, the display changes in the order of
“1000->0100->0010->0001”. This change is synchronized with
the J612: EXT ALARM output (ON/OFF).
In ALARM-4 alone, ON/OFF operations are opposite to those of
ALARM-1 to 3.
1000: ALARM-1 (#1-2), 0100: ALARM-2 (#3-4),
0010: ALARM-3 (#5-6), 0001: ALARM-4 (#7-8),
NOTE:
The polarity of ALARM-1 to 4 (ON/OFF) depends on the
setting of “[Menu] -> 3-> 6, 7, 8, 9-> 9: ALARM OUT
POLARITY”.
The setting item is not available on the IMO and A types.