4.4
Initialize Setting
Initialize Setting Initialize Setting
Initialize Setting
4-17
4.4.4 ANT REVOLUTION
INITIALIZE -> 3: SCANNER -> 4
In case that the gearbox RSB-097 (42 rpm/DC motor: D8G-571) is used for the radar
FAR2xx7, the antenna speed can be switched to 36 rpm or 42 rpm. This is selected by
the ANT REVOLUTION menu.
- LO: 36 rpm,
- HI: 42 rpm
- AUTO: When the pulse length is S1 or S2: HI (42 rpm) and when it is M/L: LO
(36 rpm)
The type of the antenna motor and the PWR board determines the antenna speed. The
PWR boards for 42 rpm motor are 03P9339-B, 03P9339-D and 04P9338-D types.
See page. 4-67 for details.
Note: Power system for antenna motor
The ANT ON (High) signal from the SPU board is outputted in TX condition. It turns
on the power to the antenna motor.
1. In case that the antenna motor power is the DC type (RSB-097: FAR-2xx7)
ANT ON, ANT SPEED (H/L level), and B.P signals from the SPU board are
inputted to the PWR board, and the antenna rotation speed is kept constant.
See page.7-67.
BP ANT SPEED
24 rpm: 144 Hz HI: 42 rpm
36 rpm: 216 Hz Low: 36 rpm
42 rpm: 252 Hz
Fig 4.4.2 Antenna DC Motor Power Control System
ANT ON
ANT SPEED
BP
BP
SPU-013
U21
MAIN CPU
J610
ANT Motor
+24VDC 42rpm
+20VDC 36rpm
RPU-013
ANT
Control
(Speed, ON/OFF)
REG
(ANT Motor)
PWR
[SCANNER]