DP-5
D1-16
5.2 EEROM Clear
1. Press function key [F8] to open the "System" menu. To change setting, move the
cursor to "Change" on the top line. Press the [↓] key to select "Self Test", then press
[Enter] key. "Self Test" menu appears on the display.
2. Select "EEROM" on the Self Test menu, then press [Enter] key.
3. EEROM check starts automatically. ( Check Address counts up.)
4. Press [ESC] key while EEROM check is carried out.
The message "EE-ROM check completed. Press any key to escape." appears on
the display.
5. Press [C] while pressing [Ctrl] key.
6. "Self Test" menu appears on the display.
7. Turn OFF power and ON again.
8. "WRITING to EEROM" appears on the display.
9. Normal display is shown automatically about one minute later.