FS-5000/8000
A3-2
2. System settings
Change the specifications with the following key sequence.
1. Press [STO] key.
2. Enter item number (system setting No.), and press [ENT] key.
3. Setting number desired, and press [ENT] key.
Ex)
[STO] [9] [9] [0] [1] [ENT] [0] [ENT]
Reference;
A power supply is only connected with the controller unit (FS-5000C), while pressing and
holding the [ENT] key, turn on the power. Controller working individually. and system
settings of FS-5000 can be done.
2.1 System Channel List
The default settings are shown in a screened cell of setting item.
Ver-21
System setting No.
Channel
No.
Function
0 1 2 3 4
9900 Model FS-5000 FS-2500 FS-1600 FS-8000
9901 TX freq. Selection Free Limited ROM Marine
9902 N.C.
9903
Output power of transceiver unit
on MF band
400W 150W 50W
9904
Class of emission on 2182kHz
AM SSB SSB FIX
9905
TX tune
Enable Disable
Auto
(Tuning
is done when
setting TX freq.)
9906 Scan of TX channel Enable Disable
9907 Time display format Japan USA Europe
9908 Second unit display Enable Disable
9909 Display of class of emission NOR(SSB) ITU(J3E)
9910
Numerical display of check meter
data
Disable Enable
9911 Test alarm RX TX
9912 Test alarm freq. 2191kHz (Selectable)
9913 TX delay time 30ms (Selectable:5-99ms) Note) FS-8000:10ms
9914 Alarm sending time 45sec (Selectable:1-9999s)
9915 Check meter items Full Short
9916
Keyboard lock
(controlled by [*]key)
OFF Lock Intercom