FELCOM 82
H3-53
4.2 Upgrading SYSTEM, DEMOD, SYNC, DECODE, and TERM
programs
4.2.1 Using IB-581 or IB-582
To upgrade SYSTEM, DEMOD, SYNC, DECODE, and TERM programs;
1. For example, using IB-582
Press [Fn], [Alt], and [F2] simultaneously to terminate FELCOM 82 system
program.
“OK to quite system?” appears. Move the cursor to “Yes” and press [Enter] key.
Prompt
C:¥> appears.
2. Inset the floppy disk having new software into the drive.
3. Type A: and press [Enter] key. Prompt changes to A:¥>.
4. Type update command. For example, to upgrade SYSTEM program, type UPSYS
and press [Enter] key. The following data appears in turn.
A:
¥
>uppg load.bin syscpu.bin 0 0 200 1
Program upload utility Version 6.25
Copyright(c) FURUNO ELECTRIC CO.,LTD.1997,1998,1999(T.K)
uppg infile1 infile2 p1 p3 p2 p4 p5
p1:Deletion waiting time.
p2:Waiting time to write.
p3:Password output interval.
p4:ID number.
p5:Port number.(1,2...)
Erase Wait:0sec
Wait:o
Wait counter=200
Port no.=1
TARGET POWER ON.
5. Turn on the IB-282, if it is off. The program upgrading proceeds while the indication
“xxx percent completed” on the terminal unit.
6. Wait until the message “Finish version up” appears.
7. Turn off the IB-282.
8. Turn on the IB-282 to check the program revision level.
9. After updating the SYSTEM program, clear RAM contents.