6 - Maintenance
65
Service and maintenance intervals
10 hours service - Cyclone Filter
To service the Cyclone filter
1. Turn the pressure SmartValve to a function other than “Spraying”.
2. Unscrew filter lid (A).
3. Lift the lid and filter (B) from housing.
4. Turn the two locks (C) outwards to unlock the filter from the lid.
5. Separate filter from the integrated filter guide in the lid and clean
the filter.
To reassemble
1. Grease the two O-rings on the lid/filter guide. Due to small space
at lid, use a brush or similar item to grease with.
2. Mount the filter onto the recess (do not grease) in the lid/filter
guide.
3. Turn the two locks (C) inwards to lock the filter to the lid.
4. Place the filter/filter lid into housing and screw the lid until it hits
the stop.
€
DANGER! The Cyclone Filter must not be opened when the pressure SmartValve is set to “Spraying”. Otherwise,
contaminated spray liquid can escape when opening the filter and drain the main tank contents!
±
WARNING! Always wear protective clothing and gloves before opening the filter!
10 hours service - EasyClean filter
This filter has a clogging indicator as mentioned in the “Description”
chapter, but even if this indicator does not show clogging, it should be
cleaned every 10 hours.
To service filter
1. Turn the filter lid counter clockwise to open.
2. Remove lid and filter from filter housing.
3. Separate filter element from lid/filter guide.
4. Clean filter and if necessary clean the housing for larger impurities.
To reassemble
1. Grease the O-ring on the filter lid.
2. Press the filter onto filter guide/lid and be sure it is fully seated into
the guide.
3. Reassemble filter/filter lid into housing and be sure it is fully seated
in the bottom of housing.
4. Turn filter lid clockwise to close lid.
±
WARNING! Always wear protective clothing and gloves before opening the filter!
ATTENTION! If opening the filter becomes too difficult, or the filter housing needs to be drained, See “Emergency
operation - EasyClean filter” on page 80.