Percentage of Output? The OmniPL can only generate chlorine
while the filter pump is operating. Set the percentage of run time
that you desire chlorine generation. Raise this value to generate more
chlorine. Lower this value to generate less.
Is pH Reduction Enabled? Select Yes if you have a dispenser to lower pH connected to
the OmniPL.
If Yes is selected:
Are you Using Acid or CO2? Select one.
How Many Acid/CO
2
Dispensers? Select the number of Acid/CO
2
dispensers
in your system.
Which relay is it Wired to? Select the box to advance to the High Voltage Table.
This table lists all of the high voltage relays that are installed in the OmniPL.
Select the relay that is wired to the pH dispense unit. Refer to the Connection
Table for this information.
pH Setpoint - Selecting the box will allow you to change the setpoint (7.5 de-
fault). Touch the Advance button when finished.
pH Dispensing Timeout - Select a timeout interval. If the unit has been dis-
pensing for more than the selected timeout without reaching the desired level,
pH dispensing will turn off and an alarm will be displayed. Check the chemical
supply and the feeder. If both are OK, the timeout may need to be increased.
The user must clear the alarm to resume pH dispensing.
pH Extend Enabled - If enabled, the OmniPL will continue to run the filter pump
regardless of schedule until the pH level in the pool has reached the setpoint.
How Many Cleaners? - This question is for THIS BODY OF WATER ONLY. For example: If you have
2 cleaners; one for the pool Body of Water and one for the spa Body of Water, you would answer “1”
to this question.
If “1”or more is selected:
Select and Configure a Cleaner At this screen you can add, delete and configure your
cleaner(s). Select the desired cleaner, then touch the Advance button. When finished
configuring cleaner(s), you’ll be returned to this same screen. Touch the Done button
to advance to the next section of configuration. Refer to the following information when
configuring cleaner(s):
Type of Cleaner? Touch the box and select the type of cleaner used. Choices are Pres-
sure, Suction, Robotic and In-Floor.
Name of Cleaner - Touch the box and use the keyboard to name the cleaner.
Does Cleaner Have a Pump? Select whether the cleaner has a dedicated pump. If so,
the OmniPL will turn this pump on when the cleaner is scheduled to run.
41
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Question and Answer IconNeed help?

Do you have a question about the Hayward OmniPL HLPRO4NSW and is the answer not in the manual?

Hayward OmniPL HLPRO4NSW Specifications

General IconGeneral
BrandHayward
ModelOmniPL HLPRO4NSW
CategoryControl Unit
LanguageEnglish

Related product manuals