10 Zone LED Alarm Panel - Engineering Manual
15
2.10.3 - AD2510 wiring to control panel
AD2510 wiring to control panel
2.11 - 13V Supply Output
The 13V output is to power detectors which require a voltage supply (PIR detector etc). The
supply is present at all times and may be used to supply a total of 350mA.
2.12 - Set
The output marked SET becomes positive on correct Set of the system and is removed by entry
of a valid user code.