10 Zone LED Alarm Panel - Engineering Manual
22
6.2.4 - How to set zone function
In Zone Function, Security type zones can be assigned different functions. These are
1= Immediate Zone, 2 = Timed Zone, 3 = Inhibited Zone.
Immediate Zone:
Use this function when the zone is not part of an entry/exit route. When the system is SET,
activation of an immediate zone will cause a full alarm condition.
Timed Zone:
A timed zone would be used to protect an entry/exit route. Opening the door or triggering
the sensor in this type of zone when the system is SET will start the entry timer.
Inhibited Zone:
A time-inhibited zone operates as an immediate zone unless a timed zone has been operated
and a timer started. Such a zone should be utilized to allow passage between the entry/exit
door and the control panel or key pad when there are detectors present.
Set zone Immediate function
Under Engineer Menu/Setup Program, the program
Full mode is chosen. LED 1 and LED 2 is flashing.
·
Press to program Immediate Zone.
LED 3~10 ON indicate selected immediate
zones.
Default settings are on.
·
To edit the other zones press Zone number
(1~10). If selected, LED is on.
If you select Zone 2 to be immediate zone,
·
Press to accept the change
Or press to cancel.
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Day
PA
TAMP
1
2
3
4
5
6
7
8
9
10
Day
P
A
TAMP
1
2
3
4
5
6
7
8
9
10
R ES TE
1
E
S
T