10 Zone LED Alarm Panel - Engineering Manual
16
Section 3 - Factory Default Setting
Indications on the system
Indications
LED steady on indication
LED flashing indication
LED off
Internal Sound
External Device: Strobe
External Siren: Bell
Defaulting Manager code and Engineer code
- Power off the alarm unit
- Connect a lead wire between terminal [RTN-] and
[SET+]
- Power on the alarm unit. Two beep sound are heard
and All codes are reset
- Clear the siren by keying in the default Manager code
- Remove the lead wire and return to Day mode by pressing <Reset> button
System status
User code 1-2 : Not used
Holiday code : Not used
Manager code : 0123
Engineer code : 9999
Bell time : 14 minutes
Bell delay time : No delay
Rearm Count : 3 Rearms
Zone type : Security
Omit Allowed : Off
Double Knock : Off
Chime : Off
System flag
Silent PA : Off
RKP PA : On
Engineer Reset : Off
PA user Reset : On
Fire user Reset : On
Bell in Fire : On
Disable Bell Tamper : Off
Lock Engineer Code : Off
Auto walk test exit : Off
Key Switch/PTS : Off
PTS as Door Bell : Off
Strobe on SET : On
Single key SET : Off
EOLR zone : Off
EN compliant : Off
SET mode
Full mode:
Zone 1 : Timed
Zone 2 : Inhibited
Zone 3-10 : Immediate
Exit Mode : Timed Exit