2. Wiring and connection
2-5
2.2. Connection terminal of AC220V Series servo drive
2.2.1. Small type servo drive
[ FDA7001 ~ FDA7002 Terminal ]
The usage and wiring method of FDA7001~FDA7002 are as follows.
1) As the main power of the power circuit, connect the R,S and T terminal to 3 phase
AC200~230[V]. It is possible to use 2 phase 220V, then the output is lower than rated.
2) Connect the regenerated resistance between the terminals P and B.
3) At the U, V and W terminal, connect the U, V and W phase of the servo motor.
4) Ground the FG terminal. Connect the grounding wire of the servo motor with this
terminal.
5) When main power is DC voltage, supply DC280~325[V] between “P[+]” and “N[-]”.
6) Don’t supply AC power between “P[+]” and “N[-]”.
AC SERVO
Operating device
FDA7001
FDA7002
Wire thickness
AWG #16(1.25mm
2
)
Open/close device
GMC-12(13A) level product
Breaker
ABS33b(5A) level product
Noise filter
P3B4010-DA(10A) level product
External regenerated
resistance
50W 50
Open/close device and Breaker : LS Industrial Systems,
http://www.lsis.biz
♥ NOISE FILTER : Woonyoung(http://woonyoung.com), OKY (
http://www.oky.co.kr
),
ORIENT(
http://www.suntronix.com
)