2. Wiring and connection
2-11
2) Connect single-phase AC380~440[V] to the control circuit terminals r and t according
to the model's voltage specification.
3) Connect the regenerated resistance between the terminals P and B.
4) At the U, V and W terminal, connect the U, V and W phase of the servo motor.
5) Ground the FG terminal. Connect the grounding wire of the servo motor with this
terminal.
AC SERVO
operating
device
FDA7020-H
FDA7030-H
FDA7045-H
FDA7075-H
FDA7110-H
FDA7150-H
Wire
thickness
AWG #12
(3.5mm
2
)
AWG #11 (4.2mm
2
)
AWG #8 (8mm
2
)
AWG #6
(14mm
2
)
AWG #4
(22mm
2
)
Open/close
device
GMC-12 (13A)
GMC-40(35A)
MC-40(40A)
MC-50(50A)
Breaker
ABS33b (10A)
ABS33b (20A)
ABS53b (40A)
ABS53b (50A)
Noise filter
ET3RE-4030 (30A)
ET3RB-4040
ET3RB-4060
External
regenerated
resistance
250W 40
(Drawing A)
250W 40 parallel 2 units
(Drawing A)
1.6kW 15Ω
(Drawing C)
2kW 15Ω
(Drawing C)
Open/close device and Breaker : LS Industrial Systems,
http://www.lsis.biz
♥ NOISE FILTER : Woonyoung(http://woonyoung.com), OKY (
http://www.oky.co.kr
),
ORIENT(
http://www.suntronix.com
)
M4
4.3
Length :300
220
239
30
60
< Drawing A>
< Drawing B> Order Code : FDA500010S(1000W/6.25Ω)

Table of Contents