2. Wiring and connection
2-31
Absolute data
is calculated as follows.
: Current position read from encoder
: Serial data (multi turns data)
: Initial incremental pulse (Generally showed in “-“ value)
: Initial incremental pulse read from absolute encoder initialization point
(Generally shown in “-“ value and this value is stored and used in the host controller.)
: Current position necessary from customer system
: Pulse for 1 encoder revolution (Value with division ratio [P01-14] applied)
Absolute data transmission sequence
Maintain the ABS_REQ signal to “H” Level.
After 50ms, it switches to standby condition to receive the serial data. The up/down
counter for incremental pulse count is cleared to “0”.
It receives the serial data 8 byte.
After receiving the initial serial data and about 400ms past, it operates as general
incremental encoder.
ABS_REQ signal
PAO
PBO
50ms
Negative
Negative
90ms Type
60ms Min.
260ms Max.
Revolution serial data
about 15ms
Incremental
pulse
8~9ms
400ms Max.
Initial incremental pulse
A phase
B phase
Incremental pulse
A phase
B phase
Incremental pulse