Network Video Recorder User Manual
120
11.2.2 Rebuild an Array
The array status includes Functional, Degraded, and Offline. To ensure the high security and
reliability of the data stored in an array, take immediate and proper maintenance of the arrays
according its status.
Functional
No disk loss in the array.
Offline
The number of lost disks has exceeded the limit.
Degraded
If any HDD fails in the array, the array degrades. Restore it to Functional status by rebuilding the
array.
Configure a Hot Spare Disk
The hot spare disk is required for the disk array automatic rebuilding.
Steps
1. Go to Storage RAID Setup Physical Disk.
Figure 11-10 Physical Disk
2. Click of an available HDD to set it as the hot spare disk.
Automatically Rebuild an Array
The video recorder can automatically rebuild degraded arrays with the hot spare disks.
Before You Start
Create hot spare disks. For details, refer to Configure a Hot Spare Disk.
Steps
1. Go to Storage RAID Setup Array.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7600NI-I2 Series and is the answer not in the manual?

HIKVISION DS-7600NI-I2 Series Specifications

General IconGeneral
BrandHIKVISION
ModelDS-7600NI-I2 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals