1
Drain Fuel Tank Sump --- daily
1. Park the machine on a level surface with the upperstruc-
ture rotated 90° for easier access.
2. Lower the bucket to the ground.
3. Turn the auto-idle off.
IMPORTANT: The turbocharger may be damaged if the
engine is not properly shut down.
4. Run the engine at slow idle speed without load for five
minutes.
5. Turn the key switch OFF. Remove the key from the key
switch.
6. Pull the pilot control shut-off lever to the LOCK position.
7. Open drain cock (1) for several seconds to drain water
and sediment. Close the drain cock.
M1U1-07-015
1
M104-07-117