MAINTENANCE
7-75
5
Remove Travel Levers
The travel levers may be removed if desired.
1. Park the machine on a level surface.
2. Lower the bucket to the ground.
3. Turn the auto-idle switch off.
4. Turn the key switch OFF. Remove the key.
5. Pull the pilot control shut-off lever to the LOCK position.
6. Remove bolts (1) and (2) to remove levers (3) and (4)
from brackets.
NOTE: Wrench size 17 mm
Tightening torque 50 N •m (5.1 kgf •m, 37 lbf •ft)
6
Check and Replace Seat Belt
Check --- daily
Replace --- every 3 years
Always maintain the seat belt in a functional condition and
replace when necessary to ensure proper performance.
Prior to operating the machine, thoroughly examine belt
(5), buckle (6) and attaching hardware (7) and tether belt (8).
If any item is damaged or materially worn, replace the seat
belt or component before operating the machine.
We recommend that the seat belt be replaced every three
years regardless of its apparent condition.
3
M178-07-077
4
2
1
6
7
8
5
M1U1-07-008
M1U1-07-009
5
6
7
8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi 120-3 class and is the answer not in the manual?

Hitachi 120-3 class Specifications

General IconGeneral
BrandHitachi
Model120-3 class
CategoryExcavators
LanguageEnglish

Related product manuals