72 EDA51 User Guide
Install Software Updates with AutoInstall
Important: The EDA51 must have power for the entire length of the upgrade process or it could
become unstable. Do not attempt to remove the battery during the process.
1. Swipe up from the bottom of the Home screen to access all apps.
2. Tap Settings > Provisioning mode under Honeywell Settings.
3. Tap the toggle button to turn Provisioning mode On.
4. Save the upgrade file (*.zip or *.apk) in one of the following folders on the
EDA51 mobile computer:
Internal shared storage\honeywell\autoinstall
Software upgrades saved to this folder for installation, do not persist when a
Full factory reset or Enterprise data reset is performed.
IPSM card\honeywell\autoinstall
Software upgrades saved to this folder, do not persist when a Full factory
reset is performed. However, the upgrade does persist if an Enterprise data
reset is performed.
5. Swipe up from the bottom of the Home screen to access all apps.
6. Tap AutoInstall Settings and verify Autoinstall is enabled .
7. Tap Packages Update from the AutoInstall Settings screen.
If required by the app, the computer may automatically initiate a reboot before
starting the installation process. When the installation is finished, a message
appears or the unit finishes rebooting and the lock screen appears.
8. Once installation is complete, turn Provisioning mode Off.
Note: Some updates do not require the computer to restart before installation.
Optional microSD Card Method
The EDA51 comes equipped with a microSD card socket. You can install an
upgrade from a microSD card you insert in the computer.
Important: The EDA51 must have power for the entire length of the upgrade process or it could
become unstable. Do not attempt to remove the battery during the process.
1. On the EDA51, swipe up from the bottom of the Home screen to access all apps.
2. Tap Settings > Provisioning mode under Honeywell Settings.
3. Tap the toggle button to turn Provisioning mode On.
4. Tap AutoInstall Settings . Verify AutoInstall is enabled .
5. Press and hold the Power button, and then tap Power off.

Table of Contents

Other manuals for Honeywell ScanPal EDA51 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ScanPal EDA51 Series and is the answer not in the manual?

Honeywell ScanPal EDA51 Series Specifications

General IconGeneral
BrandHoneywell
ModelScanPal EDA51 Series
CategoryHandhelds
LanguageEnglish

Related product manuals